Friday, April 18, 2025

HP ILO - DL160 G6 - Missing Hardware Inventory & Monitoring Sensors

 

Intro:

Missing Hardware Inventory & Monitoring Sensors on the ILO page after an ILO firmware update? If you just upgraded the BMC ILO firmware and didn't boot the machine then the Hardware Inventory & Monitoring Sensors page will be blank.


  • You'll also notice that under the ILO Summary page, the description will read as:

Description:Proliant generic G6

instead of:

Description:DL160 G6



Fix:

  • To get this back simply boot the system.
  • Look for the line..."New Generic BMC Detected, Pre-Install a BMC SDRR/CFG". It will automatically update the BMC and the description on the summary page will change and the Monitoring Sensors page will come back.



Monitoring Sensor Data


๐Ÿ‘ฝ